To specify the load Heat flux, use one of the following methods:
Command Line: |
FEMAHFLUX |
Main Menu: |
AutoFEM | Loads/Restraints | Heat flux |
Icon: |
The load Heat flux allows the user to specify the amount of heat transferred across the unit surface area per unit of time, that is, define a specific heat flux.
Heat flux can be applied to faces of the model. For selecting faces, use the automenu option:
Selected elements are added to the list.
In the properties window of the load Heat flux it is required to specify the following parameters:
•the load magnitude;
•units: W/m2, W/cm2, BTU/s*in2.
Negative value of the heat flow signifies that through the specified face the body looses the energy.
In the 3D scene Heat flow is shown in the following way:
A typical sequence of steps for specifying Heat flux:
1.Initialize the command «Heat flux» .
2.Select a face.
3.Specify the magnitude of load.
4.Specify units.
5.Complete the command.
See also: Thermal Analysis